Fire Safety Solutions · Pune

Stop kitchen fires before they spread

Automated wet chemical suppression systems that detect the fire, cut the gas supply and discharge — in seconds, with no human intervention required. Supplied and commissioned across Pune and Maharashtra.

Free site survey · Serving Pune, Pimpri-Chinchwad and Maharashtra

0s
For a grease fire to reach the exhaust duct and become uncontrollable
0°C
Typical grease fire temperature — beyond water or dry powder control
0×
Inspections required every year under the Maharashtra Fire Prevention Act 2006
What We Supply

Five product lines. One supplier.

Procured directly from certified manufacturers, stocked for fast fulfilment, and supplied to kitchens, facilities, contractors and licensed agencies across Pune, Pimpri-Chinchwad and Maharashtra — with component supply pan-India on request.

Kitchen Fire Suppression

Pre-engineered wet chemical systems certified to UL 300 / UL 1254. Automatic detection, discharge over appliance, plenum and duct, with simultaneous gas shut-off. Sized to your cooking load at survey.

Gas Leak Detection

LPG, combustible, toxic and oxygen detection. Field transmitters with multi-zone control panels, hooters, solenoid shut-off and optional GSM alerting. PESO and CIMFR approved equipment.

Fire Detection & Alarm

Smoke and heat detectors, manual call points, response indicators, hooters and sounders, conventional and addressable panels, FRLS cable and accessories — supplied to end clients, facility teams, contractors and licensed agencies.

Fire Extinguishers

ABC dry powder, carbon dioxide, water, mechanical foam, clean agent and Class K wet chemical — portable and trolley mounted, ISI marked, with annual refilling, hydraulic testing and AMC.

Drawings & Signage

Fire safety AutoCAD layouts, evacuation plan boards, photoluminescent signage and compliance consumables — prepared for statutory submission via the certifying authority.

Equipment

The hardware behind the promise.

A sample of the certified equipment we stock and supply. Every unit ships with its manufacturer test certificate and approval copies.

Kitchen fire suppression system discharging wet chemical agent over a commercial cooking line, hood and duct

Wet Chemical Suppression System

Pre-engineered cylinder, release module, heat sensing cable and nozzles covering appliance, plenum and duct — with automatic gas shut-off on discharge.

UL 300UL 1254Auto + manual release
Flameproof combustible gas transmitter with LED display and M20 cable glands

Gas Transmitters — CI-1100 / CI-2200

Field-mounted LPG / methane / propane detectors, 0–100% LEL, cast aluminium flameproof enclosure with SS316 sensor housing. Covers up to 900 sq ft per detector. LED indication or digital display with 4–20 mA output.

PESOCIMFR / CMRIIP66IEC 60079
Four zone gas leak control panel with LCD display and zone-wise LED indication

4-Zone Gas Leak Control Panel — CI-GCP-4CH

Independent zone monitoring with LCD readout, zone-wise LEDs for power, alarm and fault, tactile silence / reset controls and audible buzzer.

230 VAC24 VDC relaysMS powder-coated
Eight channel gas leak control panel with channel-wise indication

2 / 4 / 8 Channel Panels

Multi-channel gas leak monitoring with battery backup for power failures, user-configurable spare relays and optional GSM module for remote alerts.

Battery backupGSM optional1-yr warranty
Addressable digital gas monitoring system panel with seven segment channel display

Addressable Digital Monitoring — SmartGuard

Digital gas monitoring for larger sites — 4-20mA / RS485 detector input, programmable range and resolution reading %LEL, PPM or %V/V, from 2 up to 32 channels.

Modbus optionalUp to 32 CH7-seg / LCD / HMI
Layout schematic of a kitchen fire suppression installation showing cylinder, control panel, heat sensing cable, nozzles and gas shut-off valve

Complete System, One Supply

Cylinder with valve and gauge, release control panel, remote manual pull station, audio-visual alarm, actuator, nozzles, heat sensing cable and gas shut-off valve.

Sized at site surveySingle GST invoice
How It Works

Automated. In seconds. Every time.

The suppression sequence is fully mechanical and automatic — it works at 3 a.m. with nobody in the kitchen.

1

Detect

Heat sensing cable inside the hood triggers at its rated temperature

2

Cut Gas

LPG / PNG supply valve closes automatically; the alarm sounds

3

Discharge

Wet chemical agent sprays over the cooking surface, plenum and duct

4

Suppress

Foam layer forms on the hot oil, cutting oxygen and cooling the fire

5

Resume

Recharge and reset — typically back in service within 2–4 hours

Gas Leak Detection

Detect the leak before there is a fire.

Fixed field transmitters for LPG, combustible, toxic and oxygen monitoring — flameproof cast aluminium enclosures, IP66, certified by PESO and CIMFR, wired to a multi-zone control panel with hooter and automatic solenoid shut-off.

10%
Of the lower explosion limit — the level our transmitters alarm at, well below any explosive concentration
900 sq ft
Supervised by a single detector; spaced on 10 m centres in larger areas
2–32
Channel capacity available, from a two-zone kitchen panel to a 32-channel plant system
CI-1100 combustible gas transmitter — flameproof yellow cast aluminium enclosure with LED indication
Model CI-1100

Combustible Gas Transmitter — LED Indication

LPG, propane and methane monitoring for commercial and light industrial premises

  • Detection range 0–100% LEL; alarms above 10% of the lower explosion limit
  • Detects in PPM, % LEL and % V/V; LED indication for power and gas leak
  • Self-purging semiconductor sensor — no routine recalibration required
  • Two configurable potential-free relay contacts; span and zero calibration
  • Fault diagnosis and self-test alarm LEDs with relay; 3 or 4-wire technology
  • Cast aluminium alloy or SS316 flameproof enclosure, epoxy coated, IP66
  • 12–28 VDC, under 3 W · 120 × 100 × 100 mm · 2 kg · M20 cable entries (2)
  • −20 °C to 60 °C · 0–95% RH non-condensing · wall, stand or pipe mounting
PESO CertifiedCIMFR / CMRI IP66IEC 60079-0IEC 61508
CI-2200 digital gas transmitter with live concentration display and 4-20 mA output
Model CI-2200

Digital Gas Transmitter — Display & 4–20 mA Output

Industrial monitoring with live concentration readout and plant integration

  • Digital display of gas concentration on LED display, in PPM, % LEL or % V/V
  • Analog industry-standard 4–20 mA output plus RS485 digital communication
  • Accuracy ±2% of full scale; span and zero calibration functions
  • Two configurable potential-free relay contacts
  • Fault diagnosis and self-testing alarm LEDs with relay; 3 or 4-wire technology
  • Explosion proof and weather proof, cast aluminium alloy or SS316, IP66
  • 12–28 VDC (typically 24 VDC), under 3 W · 120 × 100 × 100 mm · 2 kg
  • −20 °C to 60 °C · ambient pressure ±10% · wall, stand or pipe mounting
PESO CertifiedCIMFR / CMRI 4–20 mARS485IP66
Choosing between the two
ParameterCI-1100CI-2200
ReadoutLED indication — power and gas leakDigital LED display of live concentration
OutputRelay contacts4–20 mA analog plus RS485 digital
Best forKitchens, godowns, boiler rooms, commercial premisesPlants, refineries, laboratories, PLC or SCADA integration
AccuracyThreshold alarm at 10% LEL±2% of full scale, continuous measurement
CertificationBoth PESO and CIMFR certified, IP66, EN / IS / IEC 60079-0 and 61508 compliant
Control & annunciation
CI-GCP-2CH / 4CH / 8CH

Microcontroller Gas Alarm Panel — 2, 4 and 8 Zone

Zone-wise monitoring with 16×2 LCD, expandable to 8 zones

  • Zone-wise fire, open and short LED indication, with zone-wise testing facility
  • Mains, AC fail, fuse, charging and reverse battery indication
  • Zone-wise hooter option alongside a common hooter; zone isolation from menu
  • Reset, alarm cancel and lamp test controls; password protection
  • Extra potential-free contact for fire and fault; RS485 for repeater and mimic panels
  • Keypad for zone naming and PIN change; compatible with any detector
  • 220 VAC ±10% / 24 VDC 2.5 A · hooter output 2 A at 24 VDC · EOL 4k7 Ω per zone
  • 1.8 mm CRCA powder-coated housing · 272 × 346 × 96 mm · 4.5 kg · caramel white
2 / 4 / 8 ZoneBattery Backup RS485 RepeaterPassword Protected
CI-GCP-SmartGuard

Addressable Digital Gas Monitoring Panel

Intelligent monitoring for plants, refineries and large facilities

  • Accepts 4–20 mA or RS485 input from field gas transmitters
  • 7-segment display; optionally 4.3" LCD touchscreen or 7" HMI
  • Programmable range 0–9999 reading % LEL, PPM or % V/V
  • Resolution 0.01, 0.1 or 1, user-programmable
  • Channel capacity 2, 4, 6, 8, 16 or 32; ModBus communication optional
  • Two relay outputs at 24 VDC; durable MS housing for industrial environments
Up to 32 ChannelsModBus HMI OptionData Logging
Field Devices

Hooter-cum-Flasher & Solenoid Shut-off

The output side of the system — what actually happens on alarm

  • Combined audible and visual annunciation, minimum 85 dB, distinct from the fire alarm tone
  • Solenoid gas shut-off valve driven from the panel relay — closes the supply on alarm
  • Optional GSM module for SMS, email and voice alerts to multiple numbers
  • Repeater and mimic panels over RS485 for security desks and control rooms
85 dB MinimumAuto Gas Shut-off GSM Optional
Where it applies
Industrial Plants & Refineries Gas Godowns & Distribution Laboratories & Pharma Chemical Storage Boiler Rooms & Utilities Commercial Kitchens Hotels & Malls Hospitals & Institutional
Fire Detection & Alarm

Detectors, call points and alarm panels.

Conventional and addressable fire alarm components supplied to end clients, facility teams, fire contractors and licensed agencies across Pune.

Smoke Detectors

Photoelectric and optical types for offices, corridors, stores and guest rooms. Conventional and addressable versions.

Heat Detectors

Fixed-temperature and rate-of-rise. Used where steam, dust or grease vapour would false-alarm a smoke sensor.

Manual Call Points

Break-glass and resettable types, mounted on exit routes, stair landings and lobbies.

Response Indicators

Remote indication for detectors mounted above false ceilings or inside enclosed rooms.

Hooters & Sounders

Electronic hooters and hooter-cum-flashers for audible and visual evacuation alarm.

Conventional Panels

Zone-based fire alarm control panels with battery backup, from 2 zones upward.

Addressable Panels

Device-level identification for multi-floor and large-footprint buildings.

Cable & Accessories

FRLS and fire-survival cable, back boxes, EOL resistors, batteries and mounting accessories.

Which detector for which area
AreaRecommendedWhy
Office, corridor, guest roomSmoke detectorEarly warning on smouldering fires before flame develops
Commercial kitchenHeat detectorSteam and grease vapour cause constant false alarms on smoke sensing
Boiler room, plant roomHeat detectorHigh ambient temperature and dust make smoke detection unreliable
Store room, warehouseSmoke or heat by riskDepends on stored material, dust levels and ceiling height
Gas bank, LPG manifoldGas transmitterDetects the leak before there is a fire to detect at all
Large open volume, atriumBeam detectorPoint detectors are impractical over long spans and high ceilings
Exit routes, stairwellsManual call pointLets a person raise the alarm on the way out

On BIS certification — ask every supplier, including us

Fire detection and alarm equipment in India is progressively moving under mandatory quality control orders, with smoke detectors covered by IS 11360 within the IS/ISO 7240 framework. The certification obligation sits with the manufacturer or importer, but selling non-conforming goods is itself an offence under the BIS Act, 2016. We hold the licence copy per product line and hand it over with the goods. Check the number rather than accepting the claim.

Fire Extinguishers

The right agent for the right class of fire.

Using the wrong extinguisher can make a fire worse — water on an oil fire ejects burning liquid, and CO₂ on a deep-seated solid fire will not cool it. The table below is the selection rule we work to on survey.

ABC Dry Powder

Class A, B and C. The general-purpose extinguisher for offices, shops, corridors and most commercial premises. 1 kg to 10 kg portable; 25 kg and 50 kg trolley mounted.

Carbon Dioxide

Class B and electrical. Leaves no residue, so it is the choice for server rooms, panel rooms and around live electrical equipment. 2 kg to 9 kg; 22.5 kg trolley.

Water — Spray & Jet

Class A only. Paper, wood, textiles and general combustibles. Never on oil, cooking media or live electrical equipment. 6 L and 9 L portable.

Mechanical Foam

Class A and B. Forms a blanket over flammable liquids — fuel stores, generator rooms, paint and solvent areas. 9 L portable; 45 L and 50 L trolley mounted.

Clean Agent

Class A, B and C with no residue and low toxicity. Data centres, control rooms, laboratories and areas with sensitive equipment. 2 kg to 9 kg.

Wet Chemical — Class K

Cooking oils and fats. The only portable agent that saponifies hot oil. Required at each cooking station in a commercial kitchen. 3 L, 6 L and 9 L.

Fire class and correct agent
ClassFire involvesCorrect agentNever use
Class AWood, paper, cloth, general solidsWater, foam, ABC powder—
Class BPetrol, diesel, oil, solvents, paintFoam, ABC powder, CO₂Water jet
Class CLPG, methane and other flammable gasesABC powder — after isolating the gas supplyWater, foam
Class DCombustible metalsSpecial powder (metal-specific)Water, foam, CO₂
ElectricalLive electrical equipmentCO₂, clean agentWater, foam
Class K / FCooking oils and fatsWet chemicalWater, CO₂, dry powder

Class designations follow Indian and international convention. Extinguishers supplied carry ISI marking under the applicable quality control order; certificate copies are provided with supply.

Refilling, testing and AMC

Annual Refilling

Discharged and time-expired units refilled, re-pressurised and returned with a service certificate and updated tag.

Hydraulic Testing

Pressure testing of cylinders at the interval specified for the type, with test records for your compliance file.

AMC & Audit Support

Scheduled inspection, replacement of damaged units, and the documentation your Fire NOC or corporate EHS audit will ask for.

Where We Install

Any commercial kitchen. Any scale.

From a single two-burner cloud kitchen to multi-zone hotel kitchens with linked cylinder networks. Any cooking line with a hood and a gas supply carries the same risk profile.

Hotels & Resorts Restaurants & QSR IT Park Cafeterias Hospitals Mall Food Courts Cloud Kitchens Hostels & Canteens Institutional Messes Industrial & Gas Storage
Who we supply

End clients, facilities teams and the trade — we quote the same way for a single restaurant as for a contractor buying project material.

Hotels & Restaurants Hospitals & Nursing Homes IT Parks & Corporates Malls & Retail Factories & MIDC Units Warehouses & Godowns Schools & Hostels Fire Contractors & Agencies
Our Services

Survey. Procure. Install. Service.

One point of contact from the first measurement to the annual service visit.

Free Site Survey

We visit, measure the cooking line or gas zone, assess hood and duct configuration, and issue a full system specification, itemised BOQ and quotation — free of charge, no obligation.

Procurement & Supply

Direct procurement from certified manufacturers, with PESO, CIMFR and BIS or ISI licence copies handed over per product line. Stock held on fast-moving items for same-week supply; project material consolidated under a single GST invoice.

Installation with Authorised Partner

Installation and commissioning executed jointly with a fire agency licensed by the Directorate of Maharashtra Fire Services, who issues the statutory certificate.

Documentation & Compliance File

Drawings, datasheets, test certificates and manufacturer approvals compiled into a submission-ready file for Fire NOC, NABH, insurance and corporate EHS audits.

Maintenance, Recharge & Refilling

Six-monthly inspection, pressure and nozzle checks, detector function testing and calibration, agent recharge, extinguisher refilling and hydraulic testing — with a written service certificate and an updated tag on each unit at every visit.

Emergency Response

Post-activation reset, agent refill and re-commissioning after a discharge. Rapid response to minimise kitchen downtime — typically back in service within 2–4 hours.

GeM Portal Supply

Registered GeM supplier. Government hospitals, canteens and institutions supplied via tender routes, with the documentation each tender requires.

Warranty Support

Full manufacturer warranty passed through to you, with fault reporting, replacement parts and service calls coordinated by us on your behalf.

Clear scope, clear responsibility

Under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, statutory compliance certificates are issued by agencies licensed with the Directorate of Maharashtra Fire Services. Unity Fire Safety handles procurement, supply, project coordination and site execution, and works with authorised partner agencies for installation certification — so your Fire NOC file is complete and issued by the correct authority.

Put plainly: product approvals — PESO, CIMFR and BIS or ISI — are held by the manufacturers of the equipment we supply, and certificate copies are provided with every consignment. Unity Fire Safety is not itself a Licensed Agency with the Directorate; installation certification is issued by our authorised partner agency. We state this before quotation, not after.

Credentials

Registered. Certified. Accountable.

Established
2017
Business Status
MSME Registered
Product Approvals
PESO · CIMFR · BIS
System Standard
UL 300 / UL 1254

Approvals listed refer to certifications held by the manufacturers of the products supplied; certificate copies are provided with every consignment. Specifications are those published by the equipment manufacturers and are subject to change without notice. Nothing on this page is a quotation — final specification and price follow a site survey.

Literature

Download our catalogues.

Print-ready PDFs you can save, forward to a colleague or attach to a tender or audit file. No form to fill in — click and download.

PDF · 4 pages · 1.4 MB

Product Catalogue

Gas detection, fire alarm and extinguishers. Transmitter and panel specifications, detector selection guide, fire class chart and the full service scope.

Download
PDF · 2 pages · 0.5 MB

Company Brochure

A two-page overview — who we are, all product lines, how the suppression sequence works, where we install and the services we provide.

Download
PDF · 2 pages · 1.4 MB

Kitchen Fire Suppression

The kitchen suppression catalogue — risk data, the five-step automatic sequence, installation schematics and the full survey-to-service scope.

Download
Contact

Book a free site survey

Send your floor plan, kitchen layout, hood dimensions, gas zone drawing or an equipment list — or simply call and we will visit. You receive a written specification, itemised BOQ and quotation, with no obligation and no charge for the survey.

+91 91569 60605
Call or WhatsApp · Chaitanya M. Sainkar, Proprietor
B-211, Shoppers Orbit, Vishrantwadi,
Pune — 411015, Maharashtra
Pune city, Pimpri-Chinchwad and Pune district for survey and installation. Component supply across Maharashtra and pan-India on request.

Request a callback

Fill this in and it opens a ready-made WhatsApp message to us — nothing else to set up.

Opens WhatsApp with your message pre-filled. No data is stored on this site.